![bricscad v11 manual bricscad v11 manual](https://images.ctfassets.net/26961o1141cc/jBzShiDSkRYQNKhpyEM5L/ec70c7781f68b0a1049bb970f1f1618e/bricscad-ui-mechanical-2-2-2.png)
- #Bricscad v11 manual how to
- #Bricscad v11 manual install
- #Bricscad v11 manual manual
- #Bricscad v11 manual registration
- #Bricscad v11 manual windows 7
Except for a mysterious black splotch in the layer dropdown, it looked and felt very much like Bricscad on Windows. Bricscad v11 on Ubuntu Application MenuĪfter installation, Bricscad fired right up.
#Bricscad v11 manual install
I downloaded the Debian package of Bricscad v11 Pro and Ubuntu’s Software Center installed it much like Windows Installer would install an MSI file on Windows. Installing Bricscad went off without a hitch. Installing Ubuntu was straightforward, and I had no problems.
#Bricscad v11 manual windows 7
For that, I chose Ubuntu 10.10 32-bit running on a VMWare Workstation 7.1 virtual machine hosted on my Windows 7 64-bit workstation. The first order of business was getting familiar with Linux.
![bricscad v11 manual bricscad v11 manual](https://demo.pdfslide.tips/img/642x865/reader024/reader/2021022400/5a9580287f8b9ab6188c4a42/r-1.jpg)
When I heard that Bricsys had shipped Bricscad for Linux, I was anxious to get to work on supporting the Linux platform. Posted on Categories Technical Tags Autodesk, Bricscad, BRX, COM, ObjectARX, programming, Visual Studio, Windows 1 Comment on Registering an ARX/BRX module as a COM server OpenDCL 6
#Bricscad v11 manual manual
A bonus side effect of the manual registration approach is that a normal uninstall reliably removes all traces of the COM server registration.
#Bricscad v11 manual registration
Once you have created the registry values manually, disable all other forms of COM server registration such as wizard-generated runtime registration or automatic “self-registration” at install time. Windows Registry Editor Version 1.0 Type really not that complicated for a single module. The work can be tedious to create all the values for multiple modules in scenarios where you support multiple AutoCAD and/or Bricscad versions or platforms, but these values typically don’t change over the life of the project, so it only needs to be done once. The type library and object class version numbers should match your actual version numbers as well, and of course is the installation target directory that will be resolved at install time.
![bricscad v11 manual bricscad v11 manual](https://i.ytimg.com/vi/twRzSlEGuMw/maxresdefault.jpg)
The template uses special characters as placeholders for the actual values: $$ is the human readable ProgID name, # is the COM object’s CLSID, ** is the filename of your ARX module, and %% is the type library GUID.
![bricscad v11 manual bricscad v11 manual](https://1.bp.blogspot.com/-DjFid08m4vk/XyKlbT6pvlI/AAAAAAAAAnk/aNriZZ-EKxkg7PIFQwHPubYuoJaDhnO6gCLcBGAsYHQ/s499/518W5N0OC4L._SX352_BO1%2C204%2C203%2C200_.jpg)
If you use Visual Studio deployment projects, this is the only way to batch import registry values into the installation script. I’ve provided a minimal template for a registry script that registers a single COM object and ProgID. Most installation script software can import Windows registry script (.reg) files, so it’s often helpful (and more maintainable) to create a registry script file manually, then simply import the. In most cases, this is all that is needed, however you may also need to register a “ProgID” in HKCR if a script or in-process module needs to be able to connect to the server via human-readable ProgID. VBA, AutoLISP) it must register a type library in HKCRTypeLib. If the COM server needs to support OLE Automation (e.g. It’s not difficult, though it might be time consuming initially if your server implements a lot of COM objects.Īt a minimum, a COM server must register at least one COM class under HKCRCLSID. RegSvr32 will fail with errors like “The module failed to load” or the even less helpful “The specified module could not be found.” There are some kludgy ways to get RegSvr32 to work anyway, but the simplest and most reliable way to solve this problem is to forget RegSvr32 and just add the needed registry values manually into your installer script. The reason it doesn’t work is because ARX modules cannot be loaded outside the AutoCAD or Bricscad process. There is only one reliable way to register COM servers, and that’s doing it at install time under elevated privileges.Ī normal Windows application might accomplish install-time registration by calling RegSvr32 after the files are copied to the destination folder, but this doesn’t work with ObjectARX or BRX modules. In the old days before anyone cared about user permissions, registration could be safely accomplished at runtime, even via AutoLISP. Unfortunately runtime COM server registration just doesn’t work reliably any more under limited user accounts, not to mention registry redirection on 64-bit platforms.
#Bricscad v11 manual how to
If you’re developing ARX modules that need to be registered as a COM server, you’re faced with some decisions about how to register them.